Thank you for your reply...
Here is what I typed in and the errors I received:
Code:
INSERT INTO HoldTable(QuoteType, QuoteQuantity, Initiator, DueDate, ReleasedForProcessing, GivenToQuoteGroup, GivenToCustomer, Customer, CustomerContact, ContactPhone, Vehicle, CustomerPartNumber, StantPartNumber, Description, Application, ApplicationType, ModelYear, ProductLife, TargetPrice, VolumeYear1, VolumeYeat2, VolumeYear3 , VolumeYear4, Hyperlink1, Hyperlink2, Hyperlink3, Hyperlink4, Hyperlink5, MarkedPrint, CustomerPrints, CompletePrints, Samples, DetailedDescription, MaterialSpecification, BOM, AssemblyWeight, AnnualValidation, Prototype, Prelaunch, Production, SpecialCharacteristics, ConceptDeliverable, PrototypesDeliverable, _
PilotRunDeliverable , PPAPDeliverable, ProductionDeliverable, DevelopmentSite, ProductConfig1, ProductConfig2, ProductConfig3, PatentIssues, PatentIssues1, TechAssump1, TechAssump2, TechAssump3, KnownLimit1, KnownLimit2, KnownLimit3, MfgAssumpt1, MfgAssumpt2, MfgAssumpt3, Equipment, TestAssumpt1, TestAssumpt2, TestAssumpt3 , PackagingType, Timing, Location, AdditionalStaffApproval, BAUD, GeneralManager, ManagingDirector, DivQualMan, DirectorEng, ProdEgr, QualityEng, MfgEng, ToolEng, TestingReqd, AudtiTestingReqd, LabFixturesReqd, GagesRqd, RejectRate, TestingDescription, CustomerSpecification, ApplicableStandards, _
PerformanceDescription , AsmDwgsComplete, CompDwgComplete, BOMComplete, DwgDescription, AssemblyEquipmentREqd, TestEquipmentReqd, TypeOfDateCodeReqd, MfgDescription, IncomingReq, OutgoingReq, InternalMaterialreq, PackagingDescription, GanttCompleted, Approval1, Approval2, Approval3, Approval4, Approval5, AdditonalInformation, AdditionalExistingVolume , RDTestingFixturesRequired, RDTestingRequired, RDDescription, PVTestingRequired, DVTestingRequired)
SELECT RFQInputSheet.QuoteType, RFQInputSheet.QuoteQuantity, RFQInputSheet.Initiator, RFQInputSheet.DueDate, _
RFQInputSheet.ReleasedForProcessing, RFQInputSheet.GivenToQuoteGroup, RFQInputSheet.GivenToCustomer, RFQInputSheet.Customer, RFQInputSheet.CustomerContact, _
RFQInputSheet.ContactPhone, RFQInputSheet.Vehicle, RFQInputSheet.CustomerPartNumber, RFQInputSheet.StantPartNumber, RFQInputSheet.Description, RFQInputSheet.Application, _
RFQInputSheet.ApplicationType, RFQInputSheet.ModelYear, RFQInputSheet.ProductLife, RFQInputSheet.TargetPrice, RFQInputSheet.VolumeYear1, RFQInputSheet.VolumeYeat2, _
RFQInputSheet.VolumeYear3, RFQInputSheet.VolumeYear4, RFQInputSheet.Hyperlink1, RFQInputSheet.Hyperlink2, RFQInputSheet.Hyperlink3, RFQInputSheet.Hyperlink4, _
RFQInputSheet.Hyperlink5, RFQInputSheet.MarkedPrint, RFQInputSheet.CustomerPrints, RFQInputSheet.CompletePrints, RFQInputSheet.Samples, RFQInputSheet.DetailedDescription, _
RFQInputSheet.MaterialSpecification, RFQInputSheet.BOM, RFQInputSheet.AssemblyWeight, RFQInputSheet.AnnualValidation , RFQInputSheet.Prototype, RFQInputSheet.Prelaunch, _
RFQInputSheet.Production, RFQInputSheet.SpecialCharacteristics, RFQInputSheet.ConceptDeliverable, RFQInputSheet.PrototypesDeliverable, _
RFQInputSheet.PilotRunDeliverable, RFQInputSheet.PPAPDeliverable, RFQInputSheet.ProductionDeliverable, RFQInputSheet.DevelopmentSite, _
RFQInputSheet.ProductConfig1, RFQInputSheet.ProductConfig2, RFQInputSheet.ProductConfig3, RFQInputSheet.PatentIssues, RFQInputSheet.PatentIssues1, _
RFQInputSheet.TechAssump1, RFQInputSheet.TechAssump2, RFQInputSheet.TechAssump3, RFQInputSheet.KnownLimit1, RFQInputSheet.KnownLimit2, RFQInputSheet.KnownLimit3, _
RFQInputSheet.MfgAssumpt1, RFQInputSheet.MfgAssumpt2, RFQInputSheet.MfgAssumpt3, RFQInputSheet.Equipment, RFQInputSheet.TestAssumpt1, RFQInputSheet.TestAssumpt2, _
RFQInputSheet.TestAssumpt3, RFQInputSheet.PackagingType, RFQInputSheet.Timing, RFQInputSheet.Location , RFQInputSheet.AdditionalStaffApproval, _
RFQInputSheet.BAUD , RFQInputSheet.GeneralManager , RFQInputSheet.ManagingDirector, RFQInputSheet.DivQualMan, RFQInputSheet.DirectorEng, RFQInputSheet.ProdEgr, _
RFQInputSheet.QualityEng , RFQInputSheet.MfgEng, RFQInputSheet.ToolEng, RFQInputSheet.TestingReqd, RFQInputSheet.AudtiTestingReqd, RFQInputSheet.LabFixturesReqd, _
RFQInputSheet.GagesRqd, RFQInputSheet.RejectRate, RFQInputSheet.TestingDescription, RFQInputSheet.CustomerSpecification, RFQInputSheet.ApplicableStandards, _
RFQInputSheet.PerformanceDescription, RFQInputSheet.AsmDwgsComplete, RFQInputSheet.CompDwgComplete, RFQInputSheet.BOMComplete, RFQInputSheet.DwgDescription, _
RFQInputSheet.AssemblyEquipmentREqd, RFQInputSheet.TestEquipmentReqd, RFQInputSheet.TypeOfDateCodeReqd, RFQInputSheet.MfgDescription, RFQInputSheet.IncomingReq, _
RFQInputSheet.OutgoingReq, RFQInputSheet.InternalMaterialreq, RFQInputSheet.PackagingDescription, RFQInputSheet.GanttCompleted, RFQInputSheet.Approval1, _
RFQInputSheet.Approval2, RFQInputSheet.Approval3, RFQInputSheet.Approval4, RFQInputSheet.Approval5, RFQInputSheet.AdditonalInformation , _
RFQInputSheet.AdditionalExistingVolume, RFQInputSheet.RDTestingFixturesRequired, RFQInputSheet.RDTestingRequired, RFQInputSheet.RDDescription, _
RFQInputSheet.PVTestingRequired, RFQInputSheet.DVTestingRequired FROM RFQInputSheet
FROM RFQCopyQuery
VB Highlights "HoldTable" and gives me:
Quote:
quote:Compile error:
Expected: End of statement
VB Highlights the whole "Insert Into" statement through the end of the () and gives me:
Quote:
quote: Compile error:
Syntax error
VB highlights the first "RFQInputSheet" of the select statement and gives me:
Quote:
quote: Compile error:
Expected: Case
Any thoughts / suggestions?

Regards,
Laura

The only thing standing between you and your goal is doubt. Quit doubting yourself and you'll be able to accomplish anything!
Reply With Quote